TRAINSPOTTER

run diagnostic
source
studies/mlflow-scopes/native/scopes.sqlite
format
mlflow
run
094ea54767b24a8895e0876c978ac4c6 (1 of 6 in this source)
logging steps
0–39
axis source
step
generated
2026-11-26 02:09 UTC

A change of metric scope is not training divergence

Controlled MLflow 3.17.1 logging only: twenty improving unqualified losses followed by twenty model/dataset losses. Native SQLite exposes both in one run aggregate. The report preserves every recorded value but cannot diagnose it as one training curve.

Download the input log | Capture method and limits

Input incomplete

  • 1 MLflow metric key has linked model/dataset records. Their run-level aggregates retain all recorded values under explicit names, without mapping them to canonical diagnostic metrics. Export one model/dataset history to diagnose it; a run aggregate cannot recover its source scopes.
  • MLflow run 'mixed-dataset' (094ea54767b24a8895e0876c978ac4c6), experiment 1; recorded status FINISHED, lifecycle active.
  • MLflow SQL backends can normalize infinities to finite extremes. This reader restores native NaN flags but cannot reconstruct infinities already replaced by the backend.
  • The horizontal axis retains MLflow's caller-supplied step values; they do not establish optimizer-update counts. Native defaults can repeat step 0. Use --step-key step only when this counter measures training updates.
  • Input is incomplete; findings describe only the readable data.
0error
0warning
0info
Metric sources and point counts

Scroll the table horizontally to inspect every column.

Names used by the report and their original source
Report metricSource metricReadingsAnalysis points
loss [MLflow run aggregate]loss4040

Timing unavailable

Wall-clock timing needs an explicit training-step column; this source uses MLflow logged steps. Logging intervals cannot establish seconds per training step. Log step counts, step_time, or throughput, or select a training counter with --step-key.

Timing sources and windows

Coordinates: step (logging steps).

Default timing check: first and last 20% of observations, at least five each, without overlap. This describes those windows, not every step of the run. Direct throughput is time per reported unit (such as a sample or token). Unavailable timing does not establish stable speed.

Scroll charts horizontally to inspect the full range of logging steps.

loss [MLflow run aggregate]

Download SVG
05100102030

Findings log

No findings in the readable data. Input is incomplete.